Skip to main content

MIN-0434 rev C

Mfg XXXX, Confidential Details

Project status

CI workflow

Revision History

Rev.DCR No.DateDescriptionOriginator
X1002952022-08-25Initial ReleaseConfidential
X2005382023-03-27Remove operations related to confidential process; Add fixtures and equipment; Add inspection criteria and in-process inspection steps; Update photos; Break out operations; ClarificationsConfidential
X3006712023-06-03Add confidential material. Change solder material and confidential process. Clarify workmanship criteria.Confidential
X4007742023-08-10Change references to confidential materials for confidential process. Clarify tool usage for confidential components.Confidential
X5008592023-11-20Move subassembly steps from confidential document to assembly level.Confidential
A012252024-04-05Added clarifications on cutting confidential components in sections 7.10.1 and 7.10.2; Transfer to production.Confidential
B013412024-05-06Add confidential component and associated manufacturing steps. Update inspection criteria and clarify processes in Section 5.Confidential
C013552024-05-28Clarification and note to confidential process in Step 7.7.5Confidential

Purpose

This document details the confidential process for assembling a specialized catheter.

Scope

This manufacturing instruction applies to assembling a catheter with a confidential functional length and specifications.

Definitions

Term A – Confidential process or effect.

Term B – Confidential equipment.

Term C – Confidential potential or state.

Confidential Cable Construction

A confidential cable consists of the following confidential elements:

  • Outer Layer – Confidential material for insulation.
  • Shielding – Provides confidential shielding functionality.
  • Core Insulator – Confidential insulating material.
  • Signal Core – Central element conducting a confidential signal.

References

4.1 Internal References

  • Confidential Production and Process Control Instructions
  • Confidential Procedure, ESD Precautions
  • Confidential Catheter Assembly Instructions
  • Confidential Test and Inspection Guidelines
  • Confidential Forms and Records

4.2 External References

  • NA

Precautions

  • Handle all components according to confidential handling instructions to prevent damage.
  • Use protective gear when working with solder, flux, adhesives, and curing systems.
  • Verify UV intensity of curing systems and log measurements daily using confidential tools.

Materials & Equipment

  • Item A-001 or equivalent Guide Wire, Confidential Material, Coated
  • Item B-002 or equivalent Spatula, Dispensing, Confidential Size
  • Item C-003 or equivalent Soldering System, Confidential Model
  • Item D-004 or equivalent Confidential Micro Soldering Iron
  • Item E-005 or equivalent Confidential Tip for Soldering Iron
  • Item F-006 or equivalent Flux, Confidential Solution
  • Item G-007 or equivalent Blade Breaker
  • Item H-008 or equivalent Blade – Confidential Double Edge
  • Item I-009 or equivalent Confidential Circuit Board Holder
  • Item J-010 or equivalent Tubing, Confidential Dimensions
  • Item K-011 or equivalent UV Curing System, Confidential Model
  • Item L-012 or equivalent UV Intensity Meter
  • Item M-013 or equivalent Fixture, Confidential Design
  • Item N-014 or equivalent Screwdriver, Confidential Specifications
  • Item O-015 or equivalent Adhesive Dispenser
  • Item P-016 or equivalent Adhesive Mixer Nozzle, Confidential Tip
  • Item Q-017 or equivalent Syringe, Confidential Type
  • Item R-018 or equivalent Disposable Tray
  • Item S-019 or equivalent Binder Clip, Confidential Material